Product Family | Power | Topology | Applications |
Agilon | Up to 1.5kVA | Single-Phase UPS | PC and Peripherals |
Amplon | Up to 10kVA | Single-Phase UPS | Server and Network Equipment |
Ultron | Up to 500kVA | Three-Phase On-Line UPS | Datacenter and Industrial Equipment |
Modulon | Up to 200kVA | Three-Phase modular On-Line UPS | Modular Unit expansion and Redundant power supply can be achieved within a single rack |
Delta UPS systems feature the following:
Delta’s InfraSuite Data Center Infrastructure Solutions are grouped into four main modules which optimize our customers’ ability to maximize operating efficiency at the lowest cost, maintain a high level of flexibility and control for IT managers, quickly scale to meet
demand, and monitor data center solutions 24/7/365 from anywhere around the world. These modules are as follows:
The interlocking nature of the modules allows companies to implement fully integrated system architecture.
Technical Specifications | |||
Model | RT-5K RT-6K RT-10K | ||
Power Rating | 5kVA/4.5kW 6kVA/5.4kW 10kVA/9kW | ||
Input | Nominal Voltage Voltage Range | 200/208/220/230/240 Vac (single phase) 100 ~ 300 Vac* | 5/6 kVA + Battery Pack |
Current Harmonic Distortion | < 5% (full load) | ||
Power Factor | > 0.99 (full load) | ||
Frequency | 40 ~ 70 Hz | ||
Electrical Connection | Terminal block | ||
Output | Voltage | 200/208/220/230(default)/240 Vac (single phase) | |
Voltage Harmonic Distortion | < 2% (linear load), <3% (non-linear load) | ||
Voltage Regulation | ± 1% (static); ± 2% (typical) | 10 kVA + Battery Pack | |
Frequency | 50 or 60 ± 0.05 Hz | ||
Overload Capability | 106 ~ 110%: 10 minutes; 111 ~ 125%: 5 minutes; 126 ~ 150%: 30 seconds | ||
Electrical Connection | Terminal block | ||
Crest Factor | 3:1 | ||
Battery & Charger | Nominal Voltage | 192 Vdc 192 Vdc 240 Vdc | |
Charge Current | Built-in: maximum 4A (adjustable); | Charger Box | |
Additional charger board (optional): maximum 4A (internal installation) | |||
Electrical Connection | Exclusive cable | ||
Interface | Standard | RS232 x 1, SNMP slot x 1, Smart slot x 1, Parallel port x 1 | |
Conformance | Safety & EMC | CE, TUV, EN62040-1; CISPR 22 Class A | |
Others Features | Parallel Redundancy | 1+1 | |
Remote Control | REPO; Remote On/Off | ||
Common Battery Installation | Yes | ||
Efficiency | AC-AC | 92% (full load) | Maintenance Bypass Box |
ECO Mode | 96% (full load) | ||
Environment | Operating Temperature | 0 ~ 40ºC | |
Relative Humidity | 0 ~ 95% (non-condensing) | ||
Audible Noise | 54 dBA** | ||
Physical Dimensions | UPS | 440 x 671 x 89 mm 440 x 671 x 89 mm 440 x 623 x 131 mm | |
(WxDxH) | Battery Pack | 440 x 638 x 89 mm 440 x 638 x 89 mm 440 x 595 x 131 mm | |
Weight | UPS | 15 kg 15.5 kg 21.3 kg | |
Battery Pack | 36 kg 36 kg 66 kg |