Data Center Infrastructure Solutions

Real-time access to secure and reliable data is crucial in today’s competitive global business environment. Delta has developed a new generation of tier 3 data center solutions or above that allow companies to achieve this essential goal of high level of data center reliability. Our data center design provides IT managers with the exact tools and capabilities they need in order to effectively organize the various servers within a company.

Delta’s InfraSuite Data Center Infrastructure Solutions are grouped into four main modules which optimize our customers’ ability to maximize operating efficiency at the lowest cost, maintain a high level of flexibility and control for IT managers, quickly scale to meet demand, and monitor data center solutions 24/7/365 from anywhere around the world. These modules are as follows: Power ManagementRack and Accessoriesprecision cooling and Environmental Management System. The interlocking nature of the modules allows companies to implement fully integrated system architecture.

Micro Data Center

Delta InfraSuite is a new generation, highly integrated modular datacenter solution. It uses racks as the datacenter carrier and fully integrates all sub-systems including UPSs, cooling, power distribution, lightning protection, fire control (optional), wiring, airflow management, intelligent monitoring, and more. Delta’s modular datacenter solution offers a datacenter environment that provides safe equipment operations within the racks, and supports the development and standardizing of micro datacenters that fit into racks. In addition, Delta InfraSuite takes up very little space, allowing quick deployment within a limited space, and it provides 10 types of solutions that require 20kVA power supply capabilities.

Applications

Delta InfraSuite can be applied in micro datacenters under 50 square meters or with an IT load under 20kVA. It is suitable for regional or small business environment IT applications.

 

Optimization of total cost of ownership (TCO)

  • Energy-saving. PUE less than 1.4
    A hot or cold aisle containment system effectively isolates the mixing of cold and hot air. In rack cooling with horizontal air flow is used to reduce hot spots in datacenters. The UPS has high AC-AC efficiency up to 94% or more even at half load.

  • Space-saving, superior space efficiency
    The in-rack cooling system uses a backward centrifugal fan and the dash of the centrifugal fan is inside the cold aisle. The horizontal air flow is used to reduce resistance and shorten the distance of the cold aisle. A depth of 1200mm is perfectly integrated with the datacenter floor layout and saves foot space.

High adaptability

  • Quick deployment
    Suitable for mid/small datacenter applications such as government, education, finance or SMBs. Offers flexibility, has short construction periods, and can be expanded at any time without the need for excessive investment.

  • Availability level can be adjusted at any time
    Adjust the availability level of the system at any stage, including design, installation or operations. The power supply system and cooling system do not need redesign.

Smart management

  • Datacenter environment and security information can be connected
    Signals for the temperature and humidity of the datacenter, smoke detection, datacenter access, datacenter IP camera, and others can be connected to the standard management system. The system is plug-and-play with no need for redevelopment.

  • Whatsapp alarm and mobile APP
    While an SMS alarm requires additional charges, the use of the Whatsapp alarm not only cuts down cost, but is also more suited to current trends. Mobile APPs allow the maintenance and management staff to find out system operation information at any time and place.

  • Inbuilt access control in the system cabinet
    Prevents non-professional staff from misusing equipment such as UPS or cooling and causing system crashes. Access systems are equipped on the front and rear doors of the system cabinet and only authorized personnel can enter the password on the touchscreen to open the doors. The doors can be opened manually with keys if the access system malfunctions.

Configuration

POD

Delta’s POD solution was recently awarded “Uptime Tier III Ready” certification. With its smart and flexible architecture, this solution is suitable for small and medium enterprise applications. In addition to the integration of main systems for power, cooling, racks and monitoring, the cold or hot aisle containment also provides superior air flow management to enhance cooling efficiency. A traditional data center takes 18 to 24 months to build, while a POD requires only a few weeks or months for deployment.

Benefits of choosing Delta’s tier-ready solution

One-Stop Solution

  • The prefabricated POD is fully in-house designed, configured and pre-tested with Delta’s engineering excellence
  • Delta’s expert consulting team ensures designing and building an Uptime tier-ready data center and obtaining TCDD and TCCF certification

High Agility and Quick Deployment

  • Pay-as-you-go to meet customers’ fast-growing business requirements with standard building blocks.

Superior Flexibility and Adaptability

  • Smart architecture that is applicable to either cold or hot aisle containment.

Excellent Reliability

  • Tier III certified solution saves time and money on obtaining Uptime TCDD certification.

Comprehensive Management

  • Inbuilt DCIM solution that fully integrates environment monitoring, IP camera, door access control, motion sensor, fire suppression and more.

Containerized Data Center

In this IT intensive world with heavy data traffic, an edge datacentre acts as a caching and data-aggregation point between users and larger datacentres to ease overwhelming IT loads. Following the growing applications of edge computing, Delta is introducing a new generation of containerized datacentres with flexible power and cooling designs, quick deployment and scalable capacity for implementation anywhere. The all-in-one design not only provides one stop shopping for customers, but also realizes high system integration and reliability.

Applications

Cloud, Telecom, Edge computing and Content delivery network

Advantages

Fast deployment. Pay as you go

A traditional datacentre takes 18 to 24 months to build. With the fully modularized design concept, Delta’s containerized datacenter is flexible and scalable with only a few weeks or months for deployment to meet the rapidly growing IT needs.

Highly integrated. Highly reliable.

  • Prefabricated, pretested, and fully configured architecture with high portability for edge computing application.
  • All subsystems, such as UPS, power distribution, battery, cooling, racks and more, are well integrated.

Energy efficient. Low PUE.

  • RowCool’s continuously variable fan speed control enables high energy savings.
  • Hot aisle containment further improves cooling efficiency.
  • UPS can generate high AC-AC efficiency 95% even at 30% light load.

Comprehensive manageability

Delta’s DCIM provides a sophisticated management and monitoring solution including power, energy, assets, work orders, security, capacity management, and more.

Power Container

Cloud computing, 4G/5G and media streaming applications are driving the exponential growth of data traffic. IT managers are now facing the challenges of data center scalability for future IT expansion. As a world-leading data center solutions provider, Delta is introducing power container solutions for MW data center applications. The power container solutions feature high scalability to expand along with business growth. The agile and modular architecture can also combine with other individual modular subsystems including cooling, service, and IT containers for a complete containerized data center. Per customer requirements, Delta offers various design options and services for optimal solutions. Delta also provides total data center life cycle services, including consulting, design, simulation, implementation and after service. Delta is the trusted backup power behind large data centers enabling people to enjoy a better digital life.

Advantages

Fast Deployment
Pay as You Go
 
  • Flexible and scalable with only a few weeks or months for deployment to meet the rapidly growing IT needs.
  • Not restricted to build size (width & height).
  • Add or remove walls, or stack the modules.
High Flexibility & Agility
  • Movable and reusable for the next build.
  • Multi-sites duplication with same design.
  • Easy for maintenance and spare parts management.
  • Either AC or AC/DC converged backup power is applicable.
Highly Integrated
Highly Reliable
  • Prefabricated, pretested, and fully configured.
  • UPS, battery, cooling, fire suppression and DCIM system are well integrated.
TCO Optimization
  • Less risky. Highly predictable.
  • Minimize human errors and training cost by learning curve effect.
  • Fast deployment enables IT revenue generation at earlier phase for earlier investment payback.

Head Office

Mombasa Road
Bellway Business Park
Godown No. 3
P.O. Box 26765 – 00504, Nairobi, Kenya
Tel: (+254) 20 5144388
info@deltaenergysystems.co.ke
sales@deltaenergysystems.co.ke

Mombasa Office

Yunis Building
1st Floor (Door No. 6)
Khan Road, Off Moi Avenue
P.O. Box 3150 – 80100, Mombasa, Kenya
Tel: (+254) 20 5144332
info@deltaenergysystems.co.ke
sales@deltaenergysystems.co.ke

Kampala Office

Bitcom Delta EA Ltd
Plot 141, Kira Road,
Kamwokya
P.O. Box 75265,
Kampala, Uganda
Tel: (+256) 793 600 704
(+256) 754717233
info@deltaenergysystems.co.ke
sales@deltaenergysystems.co.ke

Tanzania Office

Victoria Noble Center
15th Floor
New Bagamoyo Road
P.O. Box 3034,
Dar-es-Salaam, Tanzania
Tel: (+255) 22 2762015
(+255) 765435 363
info@deltaenergysystems.co.ke
sales@deltaenergysystems.co.ke

Copyright © 2020 | Delta Energy Systems (K) Ltd | All Rights Reserved

Let's Chat
1
Need help? Chat Here
Let's Chat
Hello,
How can we help?